説明

フルーク ii910 音響イメージカメラ is engineered to locate partial discharge, corona discharge as well as gas and vacuum leaks. The フルーク ii910 acoustic imaging camera’s groundbreaking technology is a cost efficient, safe, effective, and comfortable tool for teams who inspect and maintain power distribution and industrial high voltage equipment.

Fluke ii910 Features

  • Partial discharge detection and PD testing
  • Finding and fixing PD to save on energy and cut costs
  • Capture and analyze partial discharge
  • One button capture
  • 7” display touchscreen

Fluke ii910 Specifications

センサー
Frequency band 2 kHz to 100 kHz
Detection range 0.5 to > 120 meters (1.6 to > 393 feet)*
視野 63 ° ± 5 °
Nominal frame rate 25 FPS
*Depending on ambient conditions

 

内蔵デジタルカメラ(可視光)
Field of View (FOV) 63 ° ± 5 °
集中 固定レンズ

 

表示
サイズ 7″ LCD with backlight, under-sunlight readable
解像度 1280 x 800 (1,024,000ピクセル)
タッチスクリーン 静電容量
Acoustic image Yes, SoundMap™ image

 

Image storage
ストレージ容量 Internal memory with the capacity for 999 picture files and 20 video files
画像形式 Blended visual and SoundMap™.JPGまたは.PNG
ビデオフォーマット ブレンドされたビジュアルとサウンドマップ™.MP4
動画の長さ 5 minutes maximum
Digital export USB-C for data transfer

 

音響測定
測定範囲 12.1 dB SPL to 114.6 dB SPL ±1 dB SPL 2 kHz 4.4 dB SPL to 101.2 dB SPL ±2 dB SPL 19 kHz 12.8 dB SPL to 119.2 dB SPL ±1 dB SPL 35 kHz 19.8 dB SPL to 116.1 dB SPL ±3 dB SPL 52 kHz 41.4 dB SPL to 129.0 dB SPL ±1 dB SPL 80 kHz 54.4 dB SPL to 135.5 dB SPL ±1 dB SPL 100 kHz
Auto max/min dB gain Auto or manual, user selectable
Frequency band selection User selectable through user-made presets or manual entry

 

ソフトウェア
Ease of use 直感的なユーザーインターフェース
Trend graphs Frequency and dB scale
Spot markers dB level reading at center point of the image

 

バッテリー
Batteries (field-replaceable, rechargeable) 2 x Rechargeable Li-ion, Fluke BP291
バッテリー寿命 6 hours/battery (product includes spare battery)
バッテリー充電時間 3 hours
バッテリー充電システム External dual-bay charger, EDBC 290

 

一般仕様
標準パレット 3: Grayscale, Ironbow, Blue-Red
動作温度 0 °C to 40 °C (32 °F to 104 °F)
保管温度 -20 °C to 70 °C (-4 °F to 158 °F) Without batteries
相対湿度 10 % ~ 95 %(結露なし)
Size (H x W x L) 186 x 322  x 68 mm (7.3 x 12.7 x 2.7 inches)
重量(バッテリー含む) 1.7 kg (3.75 pounds)
Ingress Protection (IP) IP40 protection against particles 1mm or greater and dripping water
保証 2 year
Self-diagnostic notification Array-health test to identify when microphone array needs attention
対応言語 Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS準拠 はい

 

安全
General safety IEC 61010-1
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

 

Fluke ii910 Includes

  • Imager
  • AC電源およびバッテリーパック充電器(ユニバーサルACアダプターを含む)
  • Two rugged lithium ion smart battery packs
  • USBケーブル
  • キャリングケース
  • Adjustable hand strap and neck strap
参照
Fluke ii910 datasheet
製造元情報