Description
The Olympus OmniScan SX Phased Array Ultrasonic Flaw Detector features a new streamlined software interface displayed on an 8.4 in. (21.3 cm) touch screen. A single-group and non-modular instrument, the OmniScan SX is easy to operate and cost-effective for less demanding applications.
The Olympus OmniScan SX touch screen offers a full-screen mode option that maximises visibility, essentially converting many menu functions into easy touch-screen operations. The intuitive interface provides smooth menu selection, zooming, gate adjustments, cursor movements, and text and value input. These, along with other premium integrated features, including easy-to-follow setup and calibration wizards, a rapid refresh rate for both the S-scan and A-scan displays, and a fast pulse repetition frequency (PRF), make the OmniScan SX a highly efficient inspection tool.
The OmniScan SX is fully compatible with the extensive portfolio of Olympus scanners, probes and accessories, as well as with its dedicated software companions, NDT SetupBuilder and OmniPC. Combined, the complete family of software and hardware contributes to a streamlined and efficient inspection workflow, from design and setup to acquisition and analysis.
The Omniscan SX unit comes supplied with 2 fully charged batteries and can be rented either on its own (to be used with your own probes and accessories) or with a range of probe and scanner kits which may be rented in a modular format. These include TOFD, Hydroform and Rexoform kits, together with chain scanners and glide scanners. Each of these kits has a range of accessories to suit most applications. Other probes and scanners may be available on request please contact us for details.
Olympus OmniScan SX Feature
- Aperture: 16
- Number of elements: 64
- A streamlined software interface displayed on an 8.4 in. (21.3 cm) touch screen
- Single-group and non-modular
- Full-screen mode maximises visibility
- 33% lighter and 50% smaller than MX2 model
- Easy-to-follow setup and calibration wizards
- Rapid refresh rate for the S-scan and A-scan displays
- Fully compatible with the extensive portfolio of Olympus scanners, probes, accessories and software
Olympus OmniScan SX Applications
- Phased array weld inspection
- ToFD weld inspection
- P/E weld inspection
- General component inspection
- Pressure vessel inspection
- Composite inspection
- Corrosion mapping inspection
- Single group inspection
Olympus OmniScan SX Software Features
- Interleave
- Improved accessibility with more interactive menus
- Curved geometry ray-tracing for longitudinal welds
- Export C-Scan
- Onboard compound scan
- Analysis attenuation gain
- New End-View with group merge
- Optimized main menus and wizards
- Scrolling layouts for easy interpretation
Olympus OmniScan SX Specification
|
Housing |
dimensions (W x H x D) | 267 mm × 208 mm × 94 mm (10.5 in. × 8.2 in. × 3.7 in.) | |
| Weight | 3.4 kg (7.5 lb) with battery | ||
| Data Storage | Storage devices | SDHC card* or most standard USB storage devices. *Lexar® brand memory cards are recommended for optimized results. |
|
| Data file size | 300 MB | ||
| I/O Ports | USB ports | 2 USB ports, compliant with USB 2.0 specifications | |
| Audio alarm | Yes | ||
| Video output | Video out (SVGA) | ||
| I/O Lines | Encoder | 2-axis encoder line (quadrature, up, down, or clock/direction) | |
| Digital input | 4 digital TTL inputs, 5 V | ||
| Digital output | 3 digital outputs TTL, 5 V, 15 mA maximum per output | ||
| Acquisition on/off switch | Yes, through configuration of a digital input | ||
| Power output line | 5 V, 500 mA power output line (short-circuit protected) | ||
| Pace input | 5 V TTL pace input | ||
| Display | Display size | 21.3 cm (8.4 in.) (diagonal) | |
| Resolution | 800 pixels x 600 pixels | ||
| Brightness | 600 cd/m2 | ||
| Viewing angles | Horizontal: –80° to 80° Vertical: –60° to 80° | ||
| Number of colors | 16 million | ||
| Type | TFT LCD | ||
| Power Supply | Battery type | Smart Li-ion battery | |
| Number of batteries | 1 | ||
| Battery life | Minimum 6 hours under normal operating conditions | ||
| Environmental Specifications | Operating temperature range | -10 °C to 45 °C (14 ºF to 113 ºF) |
|
| Storage temperature range | –20 °C to 60 °C (–4 ºF to 140 ºF) with battery –20 °C to 70 °C (–4 ºF to 158 ºF) without battery |
||
| Relative humidity | Max. 70% RH at 45°C noncondensing | ||
| Ingress protection rating | Designed to meet requirements of IP66 | ||
| Shockproof rating | Drop-tested according to MIL-STD-810G 516.6 | ||
| Ultrasound Specifications (applies to OMNISX-1664PR) | Connectors | 1 Phased Array connector: Olympus PA connector 2 UT connectors: LEMO 00 |
|
| Number of focal laws | 256 | ||
| Probe recognition | Automatic probe recognition | ||
| Pulser/Receiver | Aperture | 16 elements | |
| Number of elements | 64 elements | ||
| Pulser | PA Channels | UT Channel | |
| Voltage | 40 V, 80 V, and 115 V | 95 V, 175 V, and 340 V | |
| Pulse width | Adjustable from 30 ns to 500 ns; resolution of 2.5 ns | Adjustable from 30 ns to 1,000 ns; resolution of 2.5 ns | |
| Pulse shape | Negative square wave | Negative square wave | |
| Output impedance | 35 Ω (pulse-echo mode); 30 Ω (pitch- catch mode) |
<30 Ω | |
| Receiver | PA Channels | UT Channel | |
| Gain | 0 dB to 80 dB, maximum input signal 550 mVp-p (full-screen height) | 0 dB to 120 dB maximum input signal 34.5 Vp-p (full-screen height) | |
| Input impedance | 60 Ω (pulse-echo mode); 150 Ω (pitch- catch mode) |
60 Ω (pulse-echo mode); 50 Ω (pulse-receive mode) |
|
| System bandwidth | 0.5 MHz to 18 MHz (NOTE: The previously stated 0.6 MHz lower limit used a strict -3 dB attenuation for the cutoff frequency.) | 0.25 MHz to 28 MHz (–3 dB) | |
| Beamforming | Scan type | Sectorial or linear | |
| Group quantity | 1 | ||
| Data Acquisition | PA Channels | UT Channel | |
| Effective digitizing frequency | Up to 100 MHz | 100 MHz | |
| Maximum pulsing rate | Up to 6 kHz (C-scan) | ||
| Data Processing | PA Channels | UT Channel | |
| Number of data points | Up to 8,192 | ||
| Real-time averaging | PA: 2, 4, 8, 16 | UT: 2, 4, 8, 16, 32, 64 | |
| Rectifier | RF, full wave, half wave +, half wave – | ||
| Filtering | 3 low-pass, 3 band-pass, and 5 high-pass filters | 3 low-pass, 6 band-pass, and 3 high-pass filters (8 low-pass filters when configured in TOFD) | |
| Video filtering | Smoothing (adjusted to probe frequency range) | ||
| Data Visualization | A-scan refresh rate | A-scan: 60 Hz; S-scan: 60 Hz | |
| Data Synchronization | On internal clock | 1 Hz to 6 kHz | |
| On encoder | On 2 axes: from 1 to 65,536 steps | ||
| Programmable Time-Corrected Gain (TCG) | Number of points | 16: One TCG (time-corrected gain) curve per focal law | |
| Maximum slope | 40 dB/10 ns | ||
| Alarms | Number of alarms | 3 | |